dc e74a7ba115
Build / Build-and-ng-test (pull_request) Failing after 2m0s
Build / Build-and-test-development (pull_request) Skipped
Lighthouse Checks / lighthouse (pull_request) Successful in 16m59s
fix(mpe_assert_abort): anchor the cut on the whole escaped separator
Cutting on the marker plus a newline still truncated a message that ends a line
with "Log Extract:", and an abort whose message merely prefixed the expected one
could pass. The appended extract always emits '\n\nLog Extract:\n', so the anchor
is that whole string (doubled form first, single as fallback): a message cannot
reproduce it by accident, and nothing is cut when neither form is present, so an
unexpected layout fails loudly instead of shortening the text.

The tail strip goes with it - the leading newlines are part of the anchor - and
the test for the doubled separator now writes the fully escaped form the estate
actually emits.

mpe_abortmessage cuts an over-long message to the room left after the prefix
instead of losing its tail to the 32767 limit, and mpe_execute's fallback skips
the trailing blank when the child's message is blank, matching the helper.
2026-10-31 02:41:54 +00:00
2026-08-27 17:21:01 +01:00
2026-05-01 11:46:10 +01:00
2023-07-13 13:44:05 +02:00
2026-10-29 16:32:45 +00:00
2023-07-25 09:09:57 +01:00
2026-10-29 16:32:45 +00:00
2026-06-15 14:42:18 +02:00

Data Controller for SAS

Control your manual data modifications!

Alternatives to Data Controller include:

  • 💾 Developing / testing / deploying / scheduling overnight batch jobs to load files from shared drives
  • 🔒 Opening (and locking) datasets in Enterprise Guide or SAS® Table Viewer to perform direct updates
  • ❓ Asking a #DBA to run validated code after a change management process
  • 🌐 Building & maintaining your own custom web application
  • 🏃 Running #SAS or #SQL updates in production

Problems with the above include:

  • Legacy 'black box' solutions with little to no testing, documentation or support
  • End users requiring direct write access to critical data sources in production
  • Upload routines that must be manually modified when the data model changes
  • Breaches due to unnecessary parties having access to the data
  • Inability to trace who made a change, when, and why
  • Reliance on key individuals to perform updates
  • Building bespoke ETL for every new data source
  • High risk of manual error / data corruption

Data Controller for SAS® solves all these issues in a simple-to-install, user-friendly, secure, documented, battle-tested web application. Available on Viya, SAS 9 EBI, and SASjs Server.

An individual Viya deploy can be done in just 2 lines of #SAS code!

filename dc url "https://git.datacontroller.io/dc/dc/releases/download/latest/viya.sas";
%inc dc;

For a multi-user deploy, using a shared system account, please see deploy docs.

For further information:

For support, contact support@4gl.io or reach out on Matrix!

Development

Lighthouse CI

This project includes automated Lighthouse performance and accessibility checks that run on pull requests. The checks ensure:

  • Accessibility Score: Minimum 1.0 (100%) median score across all tested pages

The Lighthouse CI workflow:

  1. Sets up the development environment with SASjs server and mocked services
  2. Builds and serves the Angular frontend
  3. Installs Chrome and runs lhci autorun (Lighthouse CI) against key pages
  4. Uploads results as artifacts for review

To run Lighthouse checks locally:

cd client
npm install
npm run lighthouse

Configuration is in client/lighthouserc.js (URL list, desktop preset, Chrome flags, assertions).

S
Description
Capture, Review, Approve. This repo contains the source code (and release assets) for the Data Controller application.
https://datacontroller.io
Readme
37 MiB
1 Stars 5 Watchers 0 Forks
v7.21.0
Latest
2026-10-29 16:32:53 +00:00
Languages
TypeScript 45.9%
SAS 24.5%
JavaScript 17.4%
HTML 8.7%
SCSS 2.8%
Other 0.7%