| layout | title | description | og_image |
|---|---|---|---|
| article | MPE_VALIDATIONS | The `MPE_VALIDATIONS` table enables a number of validations to be applied to the data at the point of entry - such as casing, min/max values, nullability, and the ability to generate dropdown values directly from source tables or dynamically from SAS programs. | /img/mpe_validations.png |
MPE_VALIDATIONS
The MPE_VALIDATIONS table enables a number of validations to be applied to the data at the point of entry - such as casing, min/max values, nullability, and the ability to generate dropdown values directly from source tables or dynamically from SAS programs.
A detailed breakdown is available in the validations section.
Columns
- 🔑
TX_FROM num: SCD2 open datetime TX_TO num: SCD2 close datetime- 🔑
BASE_LIB char(8): SAS Libref (8 chars) - 🔑
BASE_DS char(32): The library member name - 🔑
BASE_COL char(32): The column name - 🔑
RULE_TYPE char(32): The name of the rule to apply. RULE_VALUE char(128): The value of the ruleRULE_ACTIVE num: Set to 1 for an active rule. Set to 0 to disable the rule.