docs(options): the EDIT limits truncate the grid and warn #22

Open
hermes wants to merge 2 commits from docs/editor-limit-warning into main
pull from: docs/editor-limit-warning
3 changed files with 5 additions and 3 deletions

No files matched your search

+2
View File
@@ -23,6 +23,8 @@ Set to YES or NO to enable email alerts. This requires email options to be preco
### DC_MAXCELLS_WEBEDIT
By default, a maximum of 200,000 cells (observations multiplied by variables) can be edited in the browser at one time. This limit is applied together with [DC_MAXOBS_WEBEDIT](#dc_maxobs_webedit) - whichever is reached first.
A selection over either limit is served truncated: the grid carries the rows that fit, and a warning triangle next to the table name names the limit that was reached. Filter the table to see the rest.
The cell count matters because the cost of an EDIT screen load tracks the number of cells, not the number of rows. A 10 column table is comfortable at 250 rows, but 250 rows of a 1000 column table is 250,000 cells.
### DC_MAXOBS_WEBEDIT
+2 -2
View File
@@ -144,9 +144,9 @@ The captures below are the editor for a table with an `ORDER_DATE` column, opene
The user's clause and Data Controller's clause have to be kept apart, because Row Level Security lives in the second one. Combining them as `( user OR previous-quarter ) AND ( validity + RLS )` keeps RLS applied to both branches. Wrapping the whole existing filter instead - `( existing OR previous-quarter )` - would let the previous-quarter rows through without their RLS condition, so do not take that shortcut.
## The row cap
## The row and cell caps
`getdata` refuses a result larger than `DC_MAXOBS_WEBEDIT` (500 by default) with *Table is too big*. Widening a filter widens the result, so a hook that adds a quarter can push a table over the cap. Check the count before handing the data back, or raise the option for that table in `MPE_CONFIG`.
`getdata` truncates a result over either `DC_MAXOBS_WEBEDIT` or `DC_MAXCELLS_WEBEDIT`, whichever binds first - a wide table runs out of cells before rows, at floor(cells / columns) rows - and warns against the table name. Widening a filter widens the result, so a hook that adds a quarter can push a table over the cap: the rows past the limit never reach the browser. Check both counts before handing the data back, or raise the options for that table in `MPE_CONFIG`.
## Matching the filter chips
@@ -109,7 +109,7 @@ From that moment the changeset is an approval against `ORDERS.ORDERS`. The appro
### Other things to watch
- Concurrency behaves correctly here. Both mirrors route their submit to the same base table, so every approval locks, loads and logs against one identity - unlike the two-libref route above.
- The filter has already been applied to the empty mirror by the time the pre-edit hook runs, so a hook that reads the real table ignores the user's filter unless it re-applies it (`where %inc filtref`). On a small table you will not notice; on a large one the `DC_MAXOBS_WEBEDIT` cap will stop the edit screen with "Table is too big". [Updating the Filter in a Pre-Edit Hook](/developer-guide/filter-pre-edit-hook/) works through extending that filter.
- The filter has already been applied to the empty mirror by the time the pre-edit hook runs, so a hook that reads the real table ignores the user's filter unless it re-applies it (`where %inc filtref`). On a small table you will not notice; on a large one the `DC_MAXOBS_WEBEDIT` or `DC_MAXCELLS_WEBEDIT` cap truncates the edit screen, with a warning against the table name. [Updating the Filter in a Pre-Edit Hook](/developer-guide/filter-pre-edit-hook/) works through extending that filter.
- The hook's output must have the same columns the editor expects - the real table, minus any transaction or processing columns that Data Controller drops on load.
- The real table must itself be registered in `MPE_TABLES`. The approval screen resolves the table's audit settings from that row, so a changeset routed to a table with no registration cannot be reviewed - the submit is refused up front, naming the table.
- The mirror's `MPE_TABLES` row is read for the edit screen and the real table's for the load, so keep their `buskey`, `loadtype` and temporal column settings identical.